Hoppa till innehåll
Free shipping on orders over 3000 SEK excl. VAT! Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%
Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%The furnace drifted overnight, but no one noticed until the batch was ruinedThe air in the fridge doesn’t show the temperature of the vaccineThe Air in the Fridge Lies: How to Monitor the Real Temperature of Your Goods Without False AlarmsHow to show in seconds whether the load stayed at the right temperature and humidity during transportThe air feels heavy long before anyone measures it: how to make carbon dioxide levels visibleThe freezer showed -18 °C on Monday morning, but what happened over the weekend?The core temperature is what counts, and it only shows if someone has logged itTwo measuring points and the difference between them: how to make the temperature differential in a process visibleFour Measuring Points and a Time-Stamped Log Show Where the Heat in the Process Actually GoesYou Can’t Guess the Core Temperature of a Product: How to Document It Without Standing Next to ItVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%The furnace drifted overnight, but no one noticed until the batch was ruinedThe air in the fridge doesn’t show the temperature of the vaccineThe Air in the Fridge Lies: How to Monitor the Real Temperature of Your Goods Without False AlarmsHow to show in seconds whether the load stayed at the right temperature and humidity during transportThe air feels heavy long before anyone measures it: how to make carbon dioxide levels visibleThe freezer showed -18 °C on Monday morning, but what happened over the weekend?The core temperature is what counts, and it only shows if someone has logged itTwo measuring points and the difference between them: how to make the temperature differential in a process visibleFour Measuring Points and a Time-Stamped Log Show Where the Heat in the Process Actually GoesYou Can’t Guess the Core Temperature of a Product: How to Document It Without Standing Next to It
Item number 56-TR71A2

TandD Logger for temperature, 2 channels (external probes), wireless WiFi LAN + Bluetooth. -60 to +155 °C depending on probe. Cloud connectivity

2.599 SEK

In stock

TandD Logger for temperature, 2 channels (external sensors), wireless WiFi LAN + Bluetooth. -60 to +155 °C depending on sensor. Cloud connectivity

Request a quote 56-TR71A2

Volume discount: 5 pcs: 2% · 10 pcs: 3% · 25 pcs: 5%

  • Free shipping on orders over 3000 SEK excl. VAT
  • Data loggers with WiFi, USB and cloud service
  • Call us +46 8 753 00 04

Category: , ,

Other models in the series 16

Description

The 56-TR71A2 is TandD’s WiFi-enabled 2-channel temperature logger — a standalone unit that connects directly to your existing wireless network (or mobile hotspot) and automatically uploads measurement data via encrypted HTTPS to the T&D WebStorage Service cloud. No separate base unit or PC is required during operation.

The logger supports two channels for external thermistor probes on cable — the included fluoropolymer-coated probe measures -60 to +155 °C and withstands aggressive environments. The built-in Vaccine Mode (VFC/CDC-compliant) records Max/Min values based on logged data — perfect for pharmaceutical supply chains and vaccine refrigerators. Advanced WPA2-Enterprise (IEEE 802.1X with EAP-TLS/PEAP) makes the unit compatible with enterprise networks.

Features

  • 2 channels for external temperature probes
  • External probe measurement range: -60 to +155 °C (depending on probe)
  • Internal probe measurement range (internal sensor on electronics): -40 to +110 °C
  • Accuracy ±0.3 °C / ±0.5 °C depending on temperature range
  • WiFi 802.11 b/g/n (2.4 GHz)
  • Security: WPA-PSK, WPA2-PSK, WPA2-Enterprise (EAP-TLS, EAP-PEAP/MSCHAPv2), WPS 2.0
  • HTTPS for secure data upload
  • Vaccine Mode — Max/Min/ALM based on logged data (VFC/CDC-compliant)
  • Normal Mode — Max/Min/ALM based on current display
  • 30,000 data point memory
  • 15 fixed logging intervals: 1–60 sec or 1–60 min
  • 15 selectable upload intervals: 1 min to 24 hours (or manual)
  • Bluetooth 4.2 BLE for configuration via T&D Thermo-app
  • USB 2.0 Mini-B for PC connection (TR7 for Windows)
  • LCD with Max/Min/ALM display for both channels

Specification

Measurement channels Temperature 2 channels (external, thermistor on cable) + 1 internal sensor (at electronics)
External measurement range -60 to +155 °C (depending on probe)
Internal measurement range -40 to +110 °C
Accuracy ±0.3 °C (-20 to 80 °C), ±0.5 °C (-40 to -20 °C / 80 to 110 °C)
Resolution 0.1 °C
Response time (90 %) approx. 190 sec
Logging capacity 30,000 data points
Measurement modes Normal Mode or Vaccine Mode (VFC/CDC)
WiFi IEEE 802.11 b/g/n (2.4 GHz)
Security WPA-PSK / WPA2-PSK / WPA2-Enterprise (EAP-TLS, EAP-PEAP/MSCHAPv2), WPS 2.0
Protocols HTTP, HTTPS, SNTP, DHCP, DNS
Other interfaces Bluetooth 4.2 BLE, USB 2.0 Mini-B
Power supply 2 × AA alkaline LR6, 2 × AA Ni-MH, USB bus (5V 200 mA), AC adapter 56-AD-05A2 or 56-AD-05C2
Battery life approx. 5 days (at 1 min upload, ≥1 min logging interval)

Applications

The 56-TR71A2 is selected for pharmaceutical validation, vaccine chains (CDC/VFC), clinical research and process monitoring with strict documentation requirements. Also suitable for dual measurements (in/out heat in systems, two zones in the same chamber). For combined T+RH, see 56-TR72A2. For high precision, see 56-TR72A2-S. For thermocouples, see 56-TR75A2. For wired Ethernet instead of WiFi, see the corresponding 56-TR-7xNW series.

Additional information
Product Type

Measures

Temperatur

Communication

Trådløs Bluetooth, Trådløs WiFi

Tillbehör Givare

56-TR-0106, 56-TR-0206, 56-TR-0306, 56-TR-0406, 56-TR-0506, 56-TR-0706, 56-TR-1106, 56-TR-1220, 56-TR-1320

Tillbehör Annat

56-AD-05C2, 56-AT-76K1, 56-SO-TD1, 56-TB-3040SI, 56-TR-07K2

Tillbehör Givare

TandD Temperature Probe with TPE Coating, Length 0.6 m. Measuring Range -60 to +155 °C
56-TR-0106
370 SEK
Lägg i varukorgen
TandD Station Probe (insertion probe) for temperature, length 0.6 m. -60 to +155 °C
56-TR-0206
419 SEK
Lägg i varukorgen
TandD Temperature Probe with Stainless Steel Housing, Length 0.6 m. -60 to +155 °C
56-TR-0306
517 SEK
Lägg i varukorgen
TandD Temperature Probe with Stainless Steel Protection, Length 0.6 m. -60 to +155 °C
56-TR-0406
554 SEK
Lägg i varukorgen
TandD Temperature Probe with Stainless Steel Protection, Length 0.6 m. -60 to +155 °C
56-TR-0506
727 SEK
Lägg i varukorgen
TandD Temperature Sensor with 70 mm Stainless Steel Housing, Length 0.7 m. -60 to +155 °C
56-TR-0706
961 SEK
Lägg i varukorgen
TandD Temperature Sensor with Fluoropolymer Coating, Waterproof, Length 1.1 m. -60 to +155 °C
56-TR-1106
554 SEK
Lägg i varukorgen
TandD Temperature Probe with Stainless Steel Protection, Length 1.1 m. -60 to +155 °C
56-TR-1220
825 SEK
Lägg i varukorgen
TandD Temperature Sensor with Stainless Steel Housing, Length 2.0 m. -60 to +155 °C
56-TR-1320
961 SEK
Lägg i varukorgen

Tillbehör Annat

TandD 100-240V AC Adapter, EU Version. For charging/powering TandD loggers and base units
56-AD-05C2
370 SEK
Lägg i varukorgen
TandD Wall Mount for 56-RTR-576 & TR-76Ui
56-AT-76K1
444 SEK
Lägg i varukorgen
TandD Software DVD for TandD Logger Series 56-TR7, RTR500B, MCR, TR-7Ui & TR-5i (Windows)
56-SO-TD1
119 SEK
Lägg i varukorgen
TandD Thermal Buffer Mount (10-pack) — dampens temperature variations around the probe, e.g., for refrigeration/freezer monitoring
56-TB-3040SI
3.906 SEK
Lägg i varukorgen
TandD Wall Mount for 56-RTR-574, TR-7A2/-71A/-72A, TR-7nw, TR-73U & TR-74Ui
56-TR-07K2
148 SEK
Lägg i varukorgen