Published 12 November 2026 at 08:28
The refrigerator showed the correct temperature when someone checked the clock at 14:00. But what happened at 02:00, when the batch was in the cold room and the door had been left open for a while? In the event of a deviation, a complaint or an audit, a handwritten value from a round is not enough. What is asked for is a curve that shows the entire process, measured where the product actually is.
What it is
ThermaData Pro is a standalone temperature logger in food-grade 316 stainless steel with a fixed penetration probe measuring Ø3.3 x 50 mm. The housing is rated IP66/67, and the logger is built to withstand moisture, impacts and cleaning. The measuring range is -20 to +125 °C with a resolution of 0.1 °C and an accuracy of ±0.5 °C. The memory holds 16,000 readings.
What problems it solves
The logger replaces manual spot checks with continuous recording. You set the interval from 1 second to 255 minutes, choose to start by button, time or temperature, and set upper and lower alarm limits in the ThermaData Hub software. Afterwards you connect the logger via USB-C, and the software creates a PDF summary. It shows immediately whether the limits have been exceeded. You avoid having to interpret raw data in a spreadsheet.
When and why it is used
It is used when the temperature must be provable after the fact, not just checked at a given moment. This applies to HACCP routines, quality systems and pharmaceutical-related handling. If you want traceability, a UKAS certificate with three calibration points is available as an option.
Three areas of use
Food production. After cooking, the product must be cooled down within a certain time. If you place the logger with the probe in the core of the product, the curve shows how quickly the cooling actually went, and not just how cold the cold room was.
Heat treatment and hot holding. Up to 125 °C, the logger can handle ovens, heating cabinets and hot-fill processes. If a process is unstable, it shows up as a curve that deviates between runs.
Pharmaceuticals and laboratory. During internal transport or storage of temperature-sensitive material, the logger travels along and documents the entire journey. For fast ambient measurements, for example in dishwashers, there is a variant with a thinner fast-response probe measuring Ø1.8 x 20 mm.
Why it pays off
The cost of a logger is small compared with what a discarded product batch costs. It also saves time, since no one has to stand and read off and note down values. Above all, you have documentation when a customer or inspector asks. Without data, you often have to discard the safety margin. With data, you can show that the batch stayed within the limits.
If you want to see all probe variants and specifications, you will find them on the product page.