Hoppa till innehåll
Free shipping on orders over 3000 SEK excl. VAT! Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%
Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%The air in the fridge doesn’t show the temperature of the vaccineThe Air in the Fridge Lies: How to Monitor the Real Temperature of Your Goods Without False AlarmsHow to show in seconds whether the load stayed at the right temperature and humidity during transportThe air feels heavy long before anyone measures it: how to make carbon dioxide levels visibleThe freezer showed -18 °C on Monday morning, but what happened over the weekend?The core temperature is what counts, and it only shows if someone has logged itTwo measuring points and the difference between them: how to make the temperature differential in a process visibleFour Measuring Points and a Time-Stamped Log Show Where the Heat in the Process Actually GoesYou Can’t Guess the Core Temperature of a Product: How to Document It Without Standing Next to ItThe fridge looked like it was holding the right temperature, but what happened overnight?Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%The air in the fridge doesn’t show the temperature of the vaccineThe Air in the Fridge Lies: How to Monitor the Real Temperature of Your Goods Without False AlarmsHow to show in seconds whether the load stayed at the right temperature and humidity during transportThe air feels heavy long before anyone measures it: how to make carbon dioxide levels visibleThe freezer showed -18 °C on Monday morning, but what happened over the weekend?The core temperature is what counts, and it only shows if someone has logged itTwo measuring points and the difference between them: how to make the temperature differential in a process visibleFour Measuring Points and a Time-Stamped Log Show Where the Heat in the Process Actually GoesYou Can’t Guess the Core Temperature of a Product: How to Document It Without Standing Next to ItThe fridge looked like it was holding the right temperature, but what happened overnight?

Four Measuring Points and a Time-Stamped Log Show Where the Heat in the Process Actually Goes

Published 17 October 2026 at 02:47

The oven shows 180 °C on the display, but the product in the corner never quite finishes. Or the heating system in a building is too hot on one side and too cold on the other, and nobody knows where the difference arises. With a single-channel handheld thermometer you get one value at a time, and the value disappears as soon as you have written it down by hand. Troubleshooting then becomes guesswork.

4-channel thermometer with SD logger, with traceable calibration certificate

What the instrument is

This is a four-channel thermometer with a built-in SD logger. It handles thermocouples of types J, K, E, T, R and S on four channels, and can alternatively be used with Pt100 probes on two channels. The display shows either T1 to T4 or the differential T1-T2. The delivery includes four general-purpose type K wire probes, an SD card, six AA batteries and a hard case, so it is ready to use right away out in the field.

Which problems it solves

The biggest advantage is that several measuring points are measured simultaneously and with the same time base. Each reading is saved with the actual date and time, with a sampling interval between 1 and 3,600 seconds. A 2 GB SD card holds up to 20 million readings, which in practice is enough for measurements that run for weeks. The data is saved in Excel format and can be transferred to the computer without any special software. The offset function zeroes the instrument against a reference, making relative measurements easy. Min/max and data hold capture peaks that you would otherwise miss.

Three situations where it is used

Workshop and heat treatment. Place the probes at different locations in the oven or on the part itself. The log shows how large the temperature difference is between the front and rear of the oven, and how long the workpiece needs to reach the desired temperature.

HVAC and building operations. With the T1-T2 differential mode, you measure the difference between supply and return directly. Let the logger run for 24 hours and you can see how the heat output varies and whether an adjustment actually had an effect.

Electronics and food. When testing circuit boards, you can monitor up to four components or heat sinks under load. In food production, it is possible to document heating and cooling at several points in the same batch, with time stamps as documentation for audits.

Why the investment pays off

The time spent on manual readings and rechecks is what costs the most. A measurement that previously required a person at the oven for several hours can now run unattended. In addition, a logged process replaces the discussion about what happened with factual documentation. This version is delivered with a NIST-traceable calibration certificate, which makes the measurements usable in quality systems where traceability is required. Allow approximately five weeks of delivery time for certified products, so plan your order in advance.

If you need to compare several measuring points and be able to show the result afterwards, this is an instrument that saves more time than it costs.

Read more

More news