Published 17 November 2026 at 07:47
Someone opens the refrigerator door to fetch a package, and the display jumps up several degrees. A minute later it is back down. Was it a real temperature drop, or just air that had warmed up? Anyone responsible for medicines, vaccines or sensitive food has surely asked themselves this question, and an ordinary air probe cannot give a reliable answer.
What the ThermaGuard Pharm 102 is
The ThermaGuard Pharm 102 is a thermometer for refrigerators and freezers with two external thermistor probes, each with two meters of cable. Each probe sits in a sealed bottle that is filled with glycol solution, and 50 ml is included. The glycol works as a thermal buffer, so the probe follows the temperature of the product itself rather than the rapid swings of the air. A UKAS calibration certificate with deviations at -18 and 0 °C is also included.
Which problems it solves
The first problem is false alarms and real deviations that go unnoticed. The second is that nobody knows whether the thermometer itself reads correctly. This is where the CalCheck function comes in, letting you check the instrument against 0.0 °C (±0.1 °C) whenever you want, without sending it away. The large LCD shows the current value as well as max and min at the same time, so you can also see what has happened between two checks. Programmable high and low alarms give an audible signal and a flashing display. The instrument sits in a splash-proof IP54 housing and complies with EN 13485.
When and why it is used
When storing temperature-sensitive goods, you must be able to show that the chain has held, not just that the fridge is switched on. The max/min values and the traceable certificate let you document this during an audit or a deviation case.
Three practical uses
Pharmacies and health centers. One probe in the vaccine fridge and one in a separate medicine fridge or freezer. The alarm sounds before the temperature reaches a level where the goods must be discarded.
Food production and commercial kitchens. Two probes in different cold rooms, or one in a fridge and one in a freezer. The certificate at -18 and 0 °C covers the two most common check points.
Laboratories. Samples and reagents are often stored within tight limits. The probes in glycol show the temperature of the samples, and CalCheck provides a simple way to keep the instrument verified between external calibrations.
Why it pays off
The cost of an instrument of this kind is small compared with the value of a batch of vaccines or medicines that has to be discarded. Anyone who measures the temperature of the product also avoids unnecessary disposals following an air alarm that never reflected reality. The self-check with CalCheck reduces the need for extra rounds of calibration, and with two probes one instrument covers two measuring points.
If you want refrigeration monitoring that shows the temperature of the product and that you can check yourself, take a closer look at the ThermaGuard Pharm 102.