Published 14 November 2026 at 15:28
It’s the third hour in the conference room, or in the staff room after lunch. People get sluggish, someone opens a door, someone else complains about a draught. According to the control system, the ventilation is ”running”, but nobody knows whether the air is actually being changed as the number of people in the room increases. Without a measured value, the discussion becomes a matter of opinion.
What the RTR-576 is
TandD RTR-576 is a wireless logger with three measurement channels: carbon dioxide level (0–9 999 ppm), temperature (0–55 °C) and relative humidity (10–95 %RH), where temperature and humidity are measured with an external probe. The logger sends its values by radio to a compatible RTR-500 series base unit, with a range of up to 150 metres in line of sight. From there, the data can be forwarded to cloud storage or saved to a location of your choice, and you can also read it out on site with a data collector.
What problems it solves
The CO₂ level is one of the simplest indicators of how well a space is ventilated in relation to the number of people occupying it. The logger gives you a continuous record instead of a spot check, and you can see how the level rises as the room fills up and how quickly it drops when the air is changed. Because temperature and humidity are logged at the same time, you can distinguish between an air quality problem and a climate problem. There is also a contact output to which you can connect, for example, a buzzer or a lamp that gives an on-the-spot signal when it’s time to ventilate.
When and why it’s used
Typically, measurements are made when the ventilation is to be adjusted, when a complaint investigation needs supporting data, or when you want to know whether demand-controlled ventilation actually follows real occupancy. A week of logging reveals patterns that a single handheld instrument never captures: the Monday meeting, the shift change, the weekend when the ventilation runs at full power in an empty room.
Three areas of use
Workshop and production: In staff rooms, control rooms and training rooms with varying loads, the logger shows whether the airflow is sufficient, and the alarm output gives a clear signal before the air becomes a problem.
Food production: In packaging and preparation areas where many people work close together, CO₂, temperature and humidity can be documented in the same log. Where carbon dioxide is used in the process, for example in carbonation or fermentation, the logger gives a picture of how the room air is affected. However, it does not replace a personal gas detector where health risks are present.
Property and greenhouses: When adjusting ventilation in schools and offices, or when monitoring the climate in growing facilities, you get measurement data that can be presented to clients and contractors.
Why it pays off
Ventilation that runs too hard costs energy; ventilation that runs too weakly costs concentration and sick leave. With measurement data you can adjust in the right direction and stop guessing. A logger can also be moved between spaces, so a single instrument can provide data for several rooms over a quarter. Wireless transmission means you avoid running cables and don’t have to go around reading values manually.
See the specifications and compatible base units in our shop and build a measurement system that suits your premises.