Hoppa till innehåll
Free shipping on orders over 3000 SEK excl. VAT! Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%
Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%The air in the fridge doesn’t show the temperature of the vaccineThe Air in the Fridge Lies: How to Monitor the Real Temperature of Your Goods Without False AlarmsHow to show in seconds whether the load stayed at the right temperature and humidity during transportThe air feels heavy long before anyone measures it: how to make carbon dioxide levels visibleThe freezer showed -18 °C on Monday morning, but what happened over the weekend?The core temperature is what counts, and it only shows if someone has logged itTwo measuring points and the difference between them: how to make the temperature differential in a process visibleFour Measuring Points and a Time-Stamped Log Show Where the Heat in the Process Actually GoesYou Can’t Guess the Core Temperature of a Product: How to Document It Without Standing Next to ItThe fridge looked like it was holding the right temperature, but what happened overnight?Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%The air in the fridge doesn’t show the temperature of the vaccineThe Air in the Fridge Lies: How to Monitor the Real Temperature of Your Goods Without False AlarmsHow to show in seconds whether the load stayed at the right temperature and humidity during transportThe air feels heavy long before anyone measures it: how to make carbon dioxide levels visibleThe freezer showed -18 °C on Monday morning, but what happened over the weekend?The core temperature is what counts, and it only shows if someone has logged itTwo measuring points and the difference between them: how to make the temperature differential in a process visibleFour Measuring Points and a Time-Stamped Log Show Where the Heat in the Process Actually GoesYou Can’t Guess the Core Temperature of a Product: How to Document It Without Standing Next to ItThe fridge looked like it was holding the right temperature, but what happened overnight?
Item number 56-TR-50U2

TandD USB Communication Holder for 56-TR-5i Loggers — PC Connection

2.107 SEK

In stock

TandD USB communication holder for 56-TR-5i loggers — PC connection

Request a quote 56-TR-50U2

Volume discount: 5 pcs: 2% · 10 pcs: 3% · 25 pcs: 5%

  • Free shipping on orders over 3000 SEK excl. VAT
  • Data loggers with WiFi, USB and cloud service
  • Call us +46 8 753 00 04

Category: , ,

Other models in the series 16

Description

The 56-TR-50U2 is the communication holder required to transfer data from TandD’s TR-5i logger family to a PC. Connect the holder to your computer using the included USB Mini-B cable, place the logger screen-down on the holder, and optical communication takes over — no cables in the logger, no risk of a wet logger short-circuiting via the USB port.

TR-5i loggers do not have their own USB port (to maintain IP67 water and dust tightness) — all PC communication goes through this holder. The holder is powered by USB bus power from the computer; no external power supply is needed.

Compatible loggers

  • 56-TR-51i / 52i (temperature)
  • 56-TR-55i-TC / 55i-Pt / 55i-V / 55i-mA / 55i-P (multifunction)
  • Also compatible with discontinued models: TR-51S / 52S, TR-51A / 52

Features

  • USB 2.0 Mini-B connection to PC — USB bus-powered, no external power required
  • Optical communication with the logger (contactless)
  • Fast download: approx. 20 seconds for full logger memory
  • Compact design: 80 × 56 × 16.5 mm, weighs only 25 g
  • USB cable included

Specification

Compatible loggers 56-TR-51i, 52i, 55i-TC, 55i-Pt, 55i-V, 55i-mA, 55i-P + discontinued TR-51S/52S/51A/52
Communication USB 2.0 Mini-B (to PC), optical (to logger)
Download time approx. 20 seconds per logger
Power supply USB bus power
Dimensions 80 × 56 × 16.5 mm
Weight approx. 25 g
Operating environment -10 to +60 °C, max 90 % RH non-condensing

Included

  • 56-TR-50U2 communication holder
  • USB Mini-B cable 56-US-15C
  • Manual set with warranty certificate

Applications

The 56-TR-50U2 is a mandatory accessory for anyone who owns or purchases TR-5i loggers — without it, you cannot configure, read, or change settings on the logger. One holder is sufficient for multiple loggers (loggers are swapped individually on the holder). If you are looking for more modern loggers with Bluetooth or WiFi, see the TR-4A series (56-TR41A, 42A, 43A, 45) or the TR-7 series.

Additional information
Product Type

Tillbehör Loggers

56-TR-51I, 56-TR-52I, 56-TR-55I-MA, 56-TR-55I-P, 56-TR-55I-PT, 56-TR-55I-TC, 56-TR-55I-V

PDF (1)

Tillbehör Loggers

TandD Compact Waterproof Temperature Logger with Internal Sensor. 0–55 °C. Optical Data Transfer
56-TR-51I
1.515 SEK
Lägg i varukorgen
TandD Compact waterproof temperature logger with external probe. -60 to +155 °C depending on probe
56-TR-52I
Original price was: 1.750 SEK.Current price is: 1.697 SEK.
Lägg i varukorgen
TandD Compact Logger for 4–20 mA Current. Optical Data Transfer
56-TR-55I-MA
2.353 SEK
Lägg i varukorgen
TandD Compact logger for pulse counting, excl. sensor. Optical data transfer
56-TR-55I-P
1.774 SEK
Lägg i varukorgen
TandD Compact temperature logger for Pt-100/1000 sensors (sensor not included). Optical data transfer
56-TR-55I-PT
2.353 SEK
Lägg i varukorgen
TandD Compact logger for thermocouples (type J, K, S, T). Optical data transfer
56-TR-55I-TC
2.600 SEK
Lägg i varukorgen
TandD Compact Voltage Logger. Optical Data Transfer
56-TR-55I-V
2.353 SEK
Lägg i varukorgen