Hoppa till innehåll
Free shipping on orders over 3000 SEK excl. VAT! Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%
Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%The furnace drifted overnight, but no one noticed until the batch was ruinedThe air in the fridge doesn’t show the temperature of the vaccineThe Air in the Fridge Lies: How to Monitor the Real Temperature of Your Goods Without False AlarmsHow to show in seconds whether the load stayed at the right temperature and humidity during transportThe air feels heavy long before anyone measures it: how to make carbon dioxide levels visibleThe freezer showed -18 °C on Monday morning, but what happened over the weekend?The core temperature is what counts, and it only shows if someone has logged itTwo measuring points and the difference between them: how to make the temperature differential in a process visibleFour Measuring Points and a Time-Stamped Log Show Where the Heat in the Process Actually GoesYou Can’t Guess the Core Temperature of a Product: How to Document It Without Standing Next to ItVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%The furnace drifted overnight, but no one noticed until the batch was ruinedThe air in the fridge doesn’t show the temperature of the vaccineThe Air in the Fridge Lies: How to Monitor the Real Temperature of Your Goods Without False AlarmsHow to show in seconds whether the load stayed at the right temperature and humidity during transportThe air feels heavy long before anyone measures it: how to make carbon dioxide levels visibleThe freezer showed -18 °C on Monday morning, but what happened over the weekend?The core temperature is what counts, and it only shows if someone has logged itTwo measuring points and the difference between them: how to make the temperature differential in a process visibleFour Measuring Points and a Time-Stamped Log Show Where the Heat in the Process Actually GoesYou Can’t Guess the Core Temperature of a Product: How to Document It Without Standing Next to It
Item number 56-TR-74UI-S

TandD Logger for light level (lux), UV, temperature and humidity (high-precision model), 4 channels, USB

4.830 SEK

In stock

TandD Logger for light level (lux), UV, temperature and humidity (high-precision model), 4 channels, USB

Request a quote 56-TR-74UI-S

Volume discount: 5 pcs: 2% · 10 pcs: 3% · 25 pcs: 5%

  • Free shipping on orders over 3000 SEK excl. VAT
  • Data loggers with WiFi, USB and cloud service
  • Call us +46 8 753 00 04

Category: , ,

Other models in the series 16

Description

The 56-TR-74UI-S is the high-precision model of the 4-in-1 logger 56-TR-74UI — the same combination of light, UV, temperature, and humidity, but featuring the included SHA-3151 high-precision sensor, which provides a wider measuring range (-25 to +70 °C, 0–99 %RH) and ±2.5 %RH accuracy in the 15–35 °C / 30–80 %RH range.

Chosen for conservation environments with strict accuracy requirements — museums and archives adhering to international conservation standards (CCI, ICOM), clinical research where both light and climate must be documented with precision, and GMP-validated processes involving light exposure.

Features

  • 4 channels: light, UV, temperature, humidity
  • Light range: 0.01 lx to 130 klx
  • UV range: 0 to 30 mW/cm²
  • T/RH with high-precision SHA-3151: -25 to +70 °C / 0 to 99 %RH
  • T/RH accuracy: ±0.3 °C / ±2.5 %RH (at 15–35 °C, 30–80 %RH)
  • Cumulative light and UV exposure
  • 8,000 data point memory
  • Powered by 1 × AA battery for approx. 6 months

Specification

Measuring channels Light + UV + Temperature + Humidity — 1 channel each
Light measuring range 0 lx to 130 klx (resolution 0.01 lx)
UV measuring range 0 to 30 mW/cm²
Temperature measuring range (S) -25 to +70 °C
Humidity measuring range (S) 0 to 99 %RH
Accuracy T ±0.3 °C (10–40 °C), ±0.5 °C (other)
Accuracy RH ±2.5 %RH (15–35 °C, 30–80 %RH)
Resolution 0.1 °C / 0.1 %RH
Logging capacity 8,000 data points
Communication USB 2.0 Mini-B
Power supply 1 × AA alkaline LR6
Dimensions 55 × 78 × 18 mm

Included

  • 56-TR-74UI-S logger
  • 1 × AA alkaline battery
  • Light/UV sensor 56-ISA-3151
  • High-precision T/RH sensor 56-SHA-3151
  • USB Mini-B cable 56-US-15C
  • Manual set with warranty certificate

Applications

The 56-TR-74UI-S is suitable for conservation institutions with strict climate standards: national archives, world-class museums, cultural heritage properties, clinical research, and GMP facilities requiring combined light, UV, and climate documentation. For standard accuracy, see the 56-TR-74UI.

Additional information
Product Type

Measures

% Relative Humidity, Illumination & UV, Temperature

Communication

Wired USB

Tillbehör Givare

56-ISA-3151, 56-SHA-3151, 56-THA-3001, 56-THA-3151

Tillbehör Annat

56-AT-76K1, 56-TR-07K2, 56-US-15C

PDF (1)

Tillbehör Givare

TandD External probe for illumination (lux) and UV radiation. For TR-74Ui and RTR-574
56-ISA-3151
2.033 SEK
Lägg i varukorgen
TandD External Temperature and Humidity Sensor, High-Precision Model. Measuring Range −30 to +80 °C, 0–99 %RH
56-SHA-3151
2.501 SEK
Lägg i varukorgen
TandD External Temperature and Humidity Probe (cableless, mounts directly on logger). 0–55 °C, 10–95 %RH
56-THA-3001
1.146 SEK
Lägg i varukorgen
TandD External Temperature and Humidity Sensor with 1.5 m Cable. 0–55 °C, 10–95 %RH
56-THA-3151
1.294 SEK
Lägg i varukorgen

Tillbehör Annat

TandD Wall Mount for 56-RTR-576 & TR-76Ui
56-AT-76K1
444 SEK
Lägg i varukorgen
TandD Wall Mount for 56-RTR-574, TR-7A2/-71A/-72A, TR-7nw, TR-73U & TR-74Ui
56-TR-07K2
148 SEK
Lägg i varukorgen
TandD USB communication cable for PC for older TandD models
56-US-15C
Original price was: 222 SEK.Current price is: 220 SEK.
Lägg i varukorgen