Hoppa till innehåll
Free shipping on orders over 3000 SEK excl. VAT! Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%
Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%The air in the fridge doesn’t show the temperature of the vaccineThe Air in the Fridge Lies: How to Monitor the Real Temperature of Your Goods Without False AlarmsHow to show in seconds whether the load stayed at the right temperature and humidity during transportThe air feels heavy long before anyone measures it: how to make carbon dioxide levels visibleThe freezer showed -18 °C on Monday morning, but what happened over the weekend?The core temperature is what counts, and it only shows if someone has logged itTwo measuring points and the difference between them: how to make the temperature differential in a process visibleFour Measuring Points and a Time-Stamped Log Show Where the Heat in the Process Actually GoesYou Can’t Guess the Core Temperature of a Product: How to Document It Without Standing Next to ItThe fridge looked like it was holding the right temperature, but what happened overnight?Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%The air in the fridge doesn’t show the temperature of the vaccineThe Air in the Fridge Lies: How to Monitor the Real Temperature of Your Goods Without False AlarmsHow to show in seconds whether the load stayed at the right temperature and humidity during transportThe air feels heavy long before anyone measures it: how to make carbon dioxide levels visibleThe freezer showed -18 °C on Monday morning, but what happened over the weekend?The core temperature is what counts, and it only shows if someone has logged itTwo measuring points and the difference between them: how to make the temperature differential in a process visibleFour Measuring Points and a Time-Stamped Log Show Where the Heat in the Process Actually GoesYou Can’t Guess the Core Temperature of a Product: How to Document It Without Standing Next to ItThe fridge looked like it was holding the right temperature, but what happened overnight?
Item number 56-MCR-4TC

TandD 4-channel logger for thermocouples (types K, J, T, S, R, N, E). Measuring range -200 to +1760 °C depending on probe type. Modular — can be combined to 16 channels

4.362 SEK

In stock

TandD 4-channel logger for thermocouples (types K, J, T, S, R, N, E). Measuring range -200 to +1760 °C depending on probe type. Modular — can be combined to 16 channels

Request a quote 56-MCR-4TC

Volume discount: 5 pcs: 2% · 10 pcs: 3% · 25 pcs: 5%

  • Free shipping on orders over 3000 SEK excl. VAT
  • Data loggers with WiFi, USB and cloud service
  • Call us +46 8 753 00 04

Category: , ,

Other models in the series 16

Description

The 56-MCR-4TC is TandD’s 4-channel industrial thermocouple logger featuring a built-in touch panel, SD card storage, and galvanically isolated inputs. For larger installations, up to 4 units can be linked (16 channels total), which are synchronized via a common start and share settings.

Supports thermocouples K, J, T, S, R — covering temperatures from -199 to +1760 °C. The galvanic isolation between channels allows you to measure signals with different potential levels without crosstalk. Massive memory: up to 480,000 data points at 1 channel or 120,000 at 4 channels — this is a logger designed for long industrial processes.

NOTE: Thermocouples are NOT included — connect your own. Also available: 56-MCR-4V for voltage measurement (±50 V).

Thermocouple Compatibility

  • Type K — -199 to +1370 °C (industrial standard)
  • Type J — -199 to +1200 °C
  • Type T — -199 to +400 °C (cryogenic)
  • Type S — -50 to +1760 °C (PtRh10-Pt)
  • Type R — -50 to +1760 °C (PtRh13-Pt)

Features

  • 4 channels thermocouple with galvanic isolation
  • Measurement range -199 to +1760 °C (sensor-dependent)
  • Accuracy K/J/T: ±(0.5 + 0.003 × t) °C at ≥-100 °C; S/R: ±(1.5 + 0.003 × t) °C at ≥100 °C
  • Cold Junction compensation ±0.5 °C (10–40 °C operating range)
  • Resolution 0.1 °C
  • Groupable — up to 4 units = 16 synchronized channels
  • Massive memory: up to 480,000 / 240,000 / 160,000 / 120,000 measurements (1/2/3/4 channels)
  • SD card storage (SD/SDHC) — automatic export when internal memory is full = no data loss
  • Built-in touch panel for easy setup + trend graph display
  • Preheating function saves battery life
  • Logging interval from 100 ms to 60 min
  • Powered by 2 × AA batteries or AC adapter or USB bus

Specification

Measurement channels Temperature 4 channels — thermocouple K/J/T/S/R via screw terminals, galvanically isolated
Measurement range -199 to +1760 °C (sensor dependent)
Cold Junction compensation ±0.5 °C (10–40 °C operation), ±0.8 °C (other)
Resolution 0.1 °C
Input method Scanning, differential input, channel isolated
Logging capacity 480,000 (1 ch) / 240,000 (2 ch) / 160,000 (3 ch) / 120,000 (4 ch) measurements
Logging interval 100, 200, 500 ms / 1, 2, 5, 10, 15, 20, 30 sec / 1, 2, 5, 10, 15, 20, 30, 60 min
Group function Up to 4 units (16 channels) synchronized
Display Built-in LCD with touch panel — displays measurements, trend graph, status
Communication USB 2.0 Mini-B
External memory SD / SDHC card (manual or automatic export)
Power supply 2 × AA alkaline LR6, 2 × AA Ni-MH, AC adapter 56-AD-05A2/C2, USB bus 5V 250 mA
Battery life approx. 4.5 to 130 days (4 channels, instant value, AA alkaline)

Included

  • 56-MCR-4TC logger with touch panel
  • 2 × AA alkaline batteries
  • USB Mini-B cable 56-US-15C
  • Manual set with warranty certificate
  • NOTE: thermocouples NOT included — ordered separately
  • NOTE: SD card NOT included

Applications

The 56-MCR-4TC is selected for industrial temperature measurement using thermocouples: heat treatment furnaces, glass and metal industries, plastic recycling, heat-retaining processes, autoclaves, and calibration tasks requiring multiple thermocouples simultaneously. The group function (16 channels) makes it suitable for temperature mapping of large furnaces/chambers. For voltage measurement instead, see 56-MCR-4V. For a simpler 2-channel thermocouple model with WiFi, see 56-TR75A2.

Additional information
Product Type

Measures

Temperatuur

Communication

Bedraad USB

Tillbehör Loggers

56-TR-75NW, 56-TR45, 56-TR75A2

Tillbehör Annat

56-AD-05C2, 56-AD-06C1, 56-SO-TD1

PDF (1)

Tillbehör Annat

TandD 100-240V AC Adapter, EU Version. For charging/powering TandD loggers and base units
56-AD-05C2
370 SEK
Lägg i varukorgen
TandD 100-240V AC Adapter, EU Version. For charging/powering TandD loggers and base units
56-AD-06C1
370 SEK
Lägg i varukorgen
TandD Software DVD for TandD Logger Series 56-TR7, RTR500B, MCR, TR-7Ui & TR-5i (Windows)
56-SO-TD1
119 SEK
Lägg i varukorgen

Tillbehör Loggers

TandD Logger for Thermocouples (Type K, J, T, E, S, R), 2 Channels, Wired Ethernet/LAN. Cloud Connectivity
56-TR-75NW
2.489 SEK
Lägg i varukorgen
TandD Bluetooth Logger for Thermocouples (Type J, K, S, T, R) and Pt-100/1000 (Probe/Sensor not included). Measurement Data via Mobile App
56-TR45
1.515 SEK
Lägg i varukorgen
TandD Logger for thermocouple types K, J, T, E, S, R, 2 channels (probe not included), wireless WiFi LAN + Bluetooth. Cloud connectivity
56-TR75A2
2.887 SEK
Lägg i varukorgen