Hoppa till innehåll
Free shipping on orders over 3000 SEK excl. VAT! Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%
Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%The furnace drifted overnight, but no one noticed until the batch was ruinedThe air in the fridge doesn’t show the temperature of the vaccineThe Air in the Fridge Lies: How to Monitor the Real Temperature of Your Goods Without False AlarmsHow to show in seconds whether the load stayed at the right temperature and humidity during transportThe air feels heavy long before anyone measures it: how to make carbon dioxide levels visibleThe freezer showed -18 °C on Monday morning, but what happened over the weekend?The core temperature is what counts, and it only shows if someone has logged itTwo measuring points and the difference between them: how to make the temperature differential in a process visibleFour Measuring Points and a Time-Stamped Log Show Where the Heat in the Process Actually GoesYou Can’t Guess the Core Temperature of a Product: How to Document It Without Standing Next to ItVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%The furnace drifted overnight, but no one noticed until the batch was ruinedThe air in the fridge doesn’t show the temperature of the vaccineThe Air in the Fridge Lies: How to Monitor the Real Temperature of Your Goods Without False AlarmsHow to show in seconds whether the load stayed at the right temperature and humidity during transportThe air feels heavy long before anyone measures it: how to make carbon dioxide levels visibleThe freezer showed -18 °C on Monday morning, but what happened over the weekend?The core temperature is what counts, and it only shows if someone has logged itTwo measuring points and the difference between them: how to make the temperature differential in a process visibleFour Measuring Points and a Time-Stamped Log Show Where the Heat in the Process Actually GoesYou Can’t Guess the Core Temperature of a Product: How to Document It Without Standing Next to It

The furnace drifted overnight, but no one noticed until the batch was ruined

Published 18 November 2026 at 12:34

Many people have stood in front of a furnace in the morning and seen that the display shows the right temperature right now, while no one knows what happened during the night. The controller shows the setpoint, but not whether a door was left ajar, whether a probe drifted, or whether the heating took twice as long as usual. It then helps little that the control system looked fine when you arrived.

TandD Logger för termoelement typ K, J, T, E, S, R, 2 kanaler (givare ingår ej), trådlöst WiFi LAN + Bluetooth. Molnuppkoppling

What it is

The TandD 56-TR75A2 is a thermocouple logger with two channels. It handles types K, J, T, E, S and R, and the measuring range goes from -199 to +1760 °C depending on which thermocouple you connect. The probes are not included, but are connected to the screw terminals on the back. The logger connects to your WiFi on its own, including WPA2-Enterprise, and uploads measurement data over encrypted HTTPS to T&D WebStorage. The memory holds 30,000 data points, so nothing is lost if the network goes down for a while.

What problems it solves

It gives you an independent measurement chain alongside the process’s own control. You see the curve over the entire sequence, not just a momentary value. Two channels let you compare two points, for example furnace chamber and workpiece, or inlet and outlet. The cold junction compensation is ±0.5 °C, and the accuracy for types K, J, T and E is ±(0.5 + 0.003 × t) °C, excluding the probe itself. For types S and R it is ±(1.5 + 0.003 × t) °C.

Three use cases

In a workshop with hardening furnaces, type K is used to document that each batch actually held its temperature and time. The curve becomes evidence in the event of a complaint or audit, and you avoid copying down values by hand.

In the glass, ceramics and metal industries, types S and R are the ones that apply, since they reach 1760 °C. Few WiFi loggers can handle those temperatures. Here it is often deviations in the heating ramp that explain quality problems after the fact.

In maintenance and process monitoring, the logger is placed at a furnace or a hot water system that is difficult to reach. Alarms arrive via the web service, and you check the curve from the office. The logger also has Vaccine Mode, which records max and min based on logged data, which is useful if the same equipment is also to monitor temperature-sensitive storage.

Why it pays off

Calculate what a ruined batch costs in material, machine time and redelivery, and compare it with a logger. A single deviation caught while it is happening can justify the entire investment. In addition, the manual reading rounds disappear, and the documentation is collected and time-stamped. Configuration is done via Bluetooth and the T&D Thermo app, so installation takes little time even without IT support.

Keep in mind that the thermocouples are purchased separately. Choose the type according to temperature range and environment, and you get a logger that suits your particular process.