Published 13 October 2026 at 21:03
A meeting room where everyone gets tired after an hour. A production hall where the ventilation is running at full capacity according to the operating log, yet staff still complain about heavy air during the afternoon shift. The feeling is hard to enter into a deviation report. CO₂ levels, on the other hand, can be measured, and then the discussion becomes concrete.
What the logger is
The TandD 56-TR-76UI is an air quality logger with three channels: CO₂, temperature and relative humidity. CO₂ is measured with a built-in NDIR sensor in the range 0–9 999 ppm. Temperature and humidity are measured with the included external probe THA-3001 within 0–55 °C and 10–95 %RH, with an accuracy of ±0.5 °C and ±5 %RH respectively at 25 °C and 50 %RH. The logger stores 8,000 data points, has a display that rotates between the values, and connects directly to a computer via USB. The Windows software is free.
What problems it solves
A single reading with a handheld instrument only shows the situation at that moment. CO₂ levels vary with the number of people, operating hours and how the ventilation is adjusted, so the problem only becomes visible as a trend over several days. The logger provides that curve. Since the concentration is affected by air pressure, you can also enter the installation site’s altitude above sea level, and the logger compensates for it automatically.
The third function is the relay output. When a limit value is exceeded, the logger can control a fan, a buzzer, a siren or a PLC. This requires the optional cable 56-AC0101. Measurement then goes from documenting a problem to fixing it.
Three areas of use
Ventilation adjustment. During commissioning or in the event of complaints about the indoor climate, you log for a week under normal load. The curve shows whether the airflow is sufficient at maximum occupancy, and you can compare before and after an intervention.
Production facilities and warehouses. In enclosed spaces with many people, or where the process itself emits CO₂, the relay can start additional extraction when the level rises. Temperature and humidity are logged at the same time, which is useful when the facility also has climate requirements.
Cultivation and ripening rooms. Where CO₂ is part of the process, you need to know what the level actually is over time. The logger documents CO₂, temperature and humidity together, so you can link process deviations to the climate in the room.
Why it pays off
Without measurement data, ventilation issues often come down to guesswork. People increase the airflow throughout the entire building just to be safe, or spend money on a rebuild that wasn’t needed. With a logger, you see where the shortfall really is and can control the fan as needed instead of letting it run continuously. You also get documentation that can be presented during quality audits, workplace safety inspections or discussions with the property owner. The battery is a standard AA, and installation is done in a few minutes.
If you want to move from gut feeling to measured values, the logger is a simple first step. Read the specification and see what is included on the product page.