Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%The furnace drifted overnight, but no one noticed until the batch was ruinedThe air in the fridge doesn’t show the temperature of the vaccineThe Air in the Fridge Lies: How to Monitor the Real Temperature of Your Goods Without False AlarmsHow to show in seconds whether the load stayed at the right temperature and humidity during transportThe air feels heavy long before anyone measures it: how to make carbon dioxide levels visibleThe freezer showed -18 °C on Monday morning, but what happened over the weekend?The core temperature is what counts, and it only shows if someone has logged itTwo measuring points and the difference between them: how to make the temperature differential in a process visibleFour Measuring Points and a Time-Stamped Log Show Where the Heat in the Process Actually GoesYou Can’t Guess the Core Temperature of a Product: How to Document It Without Standing Next to ItVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%The furnace drifted overnight, but no one noticed until the batch was ruinedThe air in the fridge doesn’t show the temperature of the vaccineThe Air in the Fridge Lies: How to Monitor the Real Temperature of Your Goods Without False AlarmsHow to show in seconds whether the load stayed at the right temperature and humidity during transportThe air feels heavy long before anyone measures it: how to make carbon dioxide levels visibleThe freezer showed -18 °C on Monday morning, but what happened over the weekend?The core temperature is what counts, and it only shows if someone has logged itTwo measuring points and the difference between them: how to make the temperature differential in a process visibleFour Measuring Points and a Time-Stamped Log Show Where the Heat in the Process Actually GoesYou Can’t Guess the Core Temperature of a Product: How to Document It Without Standing Next to It

TandD MCR-4V 4-Channel Voltage Logger: When a ±50 mV Thermocouple and a ±50 V Solar Panel Are Logged by the Same Instrument

Published July 10, 2026 at 20:49

An R&D engineer is testing a new solar water heater prototype. He wants to log four things simultaneously over a 5-day test period: (1) inlet water temperature via a type K thermocouple giving ~4 mV at 100 °C, (2) outlet water temperature the same way, (3) the solar panel’s voltage across the 48 V DC bus, (4) pump current draw via a Ø 20 mm hall-effect current clamp giving 100 mV per amp. Four completely different signals, with voltages ranging from 4 mV to 48 V. Would he need four different loggers? No — a universal voltage logger with programmable input range covers it all. That’s exactly what the TandD MCR-4V is.

Why every sensor signal is actually voltage

This basic principle is odd but fundamental to industrial measurement: almost every sensor you will ever encounter delivers its output as an analog VOLTAGE. This is independent of what the sensor actually measures.

  • Thermocouples: Generate a voltage directly from the temperature difference between the measuring junction and the reference junction (Seebeck effect). Type K gives about 41 μV/°C — at 100 °C the output is ~4 mV. Range: -260 to +1260 °C gives -6 mV to +52 mV.
  • PT100/PT1000 resistance sensors: Don’t give voltage directly, but are usually connected to a TRANSMITTER that converts resistance to a standard 0-10 V or 4-20 mA signal.
  • Load cell: Strain-gauge-based, gives a few mV per volt of excitation voltage proportional to weight.
  • Pressure sensor: Piezoresistive or capacitive, gives 0-100 mV or ~4-20 mA (converted to voltage via shunt).
  • Flow meter: Standard signal 4-20 mA across shunt = 0.4-2 V.
  • pH electrodes: Give ~59 mV per pH unit at 25 °C.
  • Solar panels: Open-circuit voltage 20-48 V depending on panel size.
  • Batteries: 0-50 V depending on cell type and number of cells in series.
  • Current clamps (hall-effect): Typically 100 mV per amp.

If you have an instrument that can log voltages with a wide enough range and high enough resolution, you can log PRACTICALLY ANYTHING. That’s what the MCR-4V is designed for.

Programmable input range — the key technology

The MCR-4V has 5 selectable input ranges per channel, individually configurable:

  • ±50 mV: For thermocouples and other mV signals.
  • ±2 V: For load cell outputs and small voltage signals.
  • ±10 V: For PT100 transmitters and standard analog 0-10 V signals.
  • ±20 V: For 12 V battery monitoring, low-voltage DC systems.
  • ±50 V: For 24 V, 48 V systems, solar panels, larger battery systems.

Each channel has independent range settings. This means channel 1 can log the thermocouple’s ±50 mV, channel 2 can log the 48 V solar panel, channel 3 can log a 5 V analog transducer, and channel 4 can log a 12 V battery — all simultaneously, in the same instrument.

Resolution versus range

The advanced part: the MCR-4V’s A/D converter has fixed resolution in BITS (typically 16-bit) regardless of which range is selected. This means the resolution in VOLTS scales with the range:

  • ±50 mV / 65,536 levels = 1.5 μV resolution. For a type K thermocouple where 41 μV = 1 °C, this means 0.04 °C temperature resolution.
  • ±2 V / 65,536 levels = 61 μV resolution.
  • ±10 V / 65,536 levels = 305 μV resolution.
  • ±20 V / 65,536 levels = 610 μV resolution.
  • ±50 V / 65,536 levels = 1.5 mV resolution. For a 48 V solar panel, this is 0.003 % relative resolution — more than enough for production QC.

The optimal range is the SMALLEST one that covers the expected measurement span. If you choose ±50 V to measure a 2 V signal, you lose 25x resolution. Correct choice: select the ±2 V range for a 0-1.5 V signal.

480,000 data points of internal memory

The logger has 480,000 measurement values of internal memory per instrument. Practical implications:

  • At a 1-second sampling rate = 480,000 seconds = 5.55 days continuous.
  • At a 10-second sampling rate = 55 days.
  • At a 1-minute sampling rate = 333 days (nearly a year).
  • At a 5-second sampling rate on 4 channels = 120,000 x 4 = available across all 4 channels for 6.9 days.

If you need longer recording time, there is an SD card slot for automatic data export. A 32 GB SD card is enough for years of continuous 4-channel logging.

TandD MCR-4V 4-kanals spännings-logger DC ±50 mV till ±50 V modular

Modular scaling: up to 16 channels

The MCR-4V can be linked with up to four other MCR loggers (including the MCR-4TC for direct thermocouple input). Result: a single measurement setup with up to 16 synchronized channels.

The critical thing about this architecture is TIME SYNCHRONIZATION. With multiple logger units, it’s important that they all log their values at EXACTLY the same time — otherwise you can’t cross-reference between channels. TandD’s linking protocol ensures all loggers in the chain are synchronized to within <10 ms.

Practical scenarios where 8-16 channels are needed:

  • Multi-point thermocouple measurement in an oven (8 thermocouples in different zones).
  • Battery cell monitoring in a 12-cell battery pack (12 voltages).
  • Solar panel array monitoring with 8 individual panel voltages plus 4 thermocouples.
  • Backup battery UPS testing with multi-point monitoring.

On-device LCD trend graph

Although the MCR-4V is primarily a logger (storing data for later analysis), it has an LCD display that shows a TREND GRAPH directly on the device. This is unusual among stand-alone loggers and useful for:

  • Field diagnostics: You can see whether the measurement is working before leaving the site.
  • In-test monitoring: During a 24-hour test, you can verify on-site that the data looks reasonable without connecting a computer.
  • Alarm verification: Quick check on whether a threshold alarm triggered.

T&D graph software

After the measurement, data is exported to a computer via USB or SD card and analyzed with T&D’s ”T&D graph” software (Windows-compatible). The software offers:

  • Import of data from all MCR series loggers.
  • Interactive graphical display with zoom, cursor, statistics.
  • Export to CSV, Excel, PDF.
  • Scaling from voltage to physical unit (e.g. mV → °C using a thermocouple table).
  • Multi-channel overlay for correlation analysis.
  • Alarm threshold evaluation.

For industrial integration, an SDK is also available for importing data directly into your own analysis tools (Python, MATLAB, LabVIEW).

Battery or USB powered

The MCR-4V can be powered either by its built-in battery or via USB from a computer/USB power supply. Typical operating scenarios:

  • Battery operation, low sampling (60 s): 6-12 months of independent operation. Perfect for outdoor or field installation monitoring.
  • Battery operation, high sampling (1 s): 4-8 weeks. For shorter tests.
  • USB operation: Unlimited operating time. Perfect for lab tests or permanent installation near a computer.

Battery type: standard C-cell alkaline or lithium. User-replaceable.

Common applications

R&D labs: Combined sensor tests where multi-parameter data must be logged in sync.

Solar panel monitoring: Panel voltage + panel temperature + inverter output + load voltage over days/months for performance analysis.

Battery testing: Cell voltages under load, temperature during charging, capacity measurement.

Thermal analysis: Thermocouples at 4 different points in a product during thermal cycling.

Industrial process diagnostics: Combinations of pressure, temperature, voltage and current signals.

Maintenance diagnostics: Motor inspection tests with combined vibration and voltage measurement.

Schools and technical training: Multi-parameter measurement for physics and electronics experiments.

Structural engineering tests: Settlement monitoring, deformation measurement, thermal studies.

What you should NOT buy this for

  • AC measurements: The MCR-4V is DC-only. For AC voltage or AC current measurement, a different instrument is needed.
  • High voltages (above 50 V): 400 V electrical installation measurement requires an isolated high-voltage logger.
  • Fast transient signals: The MCR-4V’s sampling is typically 1-30 seconds per reading. For kHz signals (motor vibration, PWM signals), an oscilloscope or high-speed DAQ is required.
  • Remote monitoring: The MCR-4V does not have built-in WiFi or cellular. For remote live data, a complement is required (e.g. TandD’s RTR series or Wireless Gateway).

What you get for your money

TandD MCR-4V 4-channel voltage logger, DC ±50 mV / ±2 V / ±10 V / ±20 V / ±50 V selectable ranges per channel, 16-bit A/D resolution, 480,000 measurement values of internal memory per unit, SD card slot for auto-export, LCD trend graph display, battery- or USB-powered, USB connection to PC, modular scaling up to 16 channels via linking, T&D graph software included. 4,295 SEK per unit.

The standard instrument for multi-channel voltage logging in R&D, industrial process diagnostics, renewable energy monitoring and other applications where multiple simultaneous analog signals need to be recorded over days or weeks. The programmable input range makes it a truly universal data collector — the same instrument works for thermocouples, load cells, PT100 transmitters, solar panels and batteries. For applications with kHz signals or AC measurements, specialized alternatives are needed.

Read more: TandD MCR-4V 4-channel voltage logger in the shop →