Published 24 August 2026 at 02:36
A temperature curve from a shipment shows that something went wrong. It rarely shows where. The curve is a series of values plotted against time of day, and a timestamp says nothing about whether the goods were on a loading dock, in a truck, or in an aircraft cargo hold when the deviation occurred. Without that link, a claim turns into a debate about who had the goods at half past three.
Add a third channel — atmospheric pressure — and the curve suddenly gets a geography. Pressure drops as the plane climbs and returns when it lands, and that shape is unmistakable.
What it is
The TandD TR-73U is a handheld three-channel logger that measures temperature, humidity and atmospheric pressure simultaneously.
- Temperature and humidity via the included external probe TR-3100: 0 to +55 °C and 10 to 95 %RH
- Atmospheric pressure with a built-in sensor: 750 to 1100 hPa
- Accuracy of ±0.3 °C in the calibrated range of 0-50 °C, and ±1.5 hPa
- Resolution 0.1 °C / 1 %RH / 0.1 hPa
- 8,000 data points in total across all three channels, 15 fixed intervals from 1 second to 60 minutes
- Built-in LCD that cycles between the readings, with buttons for start, stop and interval
- Direct USB 2.0 Mini-B connection to a computer, approximately 10 months on one AA battery
- Approved to RTCA DO-160E Section 21 for radio frequency emission
The problem it solves
That approval is not a technical footnote — it is the whole point of the instrument in an aviation context. DO-160E Section 21 covers how much radio interference an electrical device is allowed to emit, and that is precisely the question that determines whether equipment may be switched on in an aircraft cabin. A logger that meets the requirement can be carried as hand luggage and run during the flight. One that doesn’t must formally be switched off — which means the part of the cold chain that is hardest to control is also the only part with no data.
Three parameters in the same unit are not the same thing as three instruments. The readings share a timestamp and a location, which means they can be read against each other. A temperature spike that coincides with a rise in humidity points to an opened door or a warm cargo hold; one that coincides with a pressure change points to a phase of flight. With three separate loggers, you instead have to trust that the clocks ran in sync.
Humidity determines what the temperature actually means. The same 25 °C is harmless at 30 %RH and a condensation risk at 90 %, because the dew point lies close to the temperature. For electronics, packaging, powders and pharmaceuticals, it is often the condensation — not the temperature itself — that does the damage, and that assessment requires both values.
One AA battery for ten months also makes the difference between an instrument that sits charged in the bag and one that has to be prepared before every assignment. That detail is often what decides whether a measurement actually gets made.
Three typical use cases
- Air freight documentation: temperature-sensitive goods where the entire journey, including the flight phase, needs to be accounted for.
- Calibration and measurement rooms: where air pressure, temperature and humidity must be recorded as boundary conditions for the measurement itself.
- Weather and environmental documentation: field measurements and construction sites, where the three parameters belong together.
Why it pays off
The cost of transport damage is rarely just the goods. It lies in the fact that nobody can show where things went wrong, which means responsibility ends up with whoever has the poorest documentation — often the shipper. A data series covering the entire route moves that discussion from opinion to evidence.
And for those who ship often, there is a second gain: when you can see in which part of the chain the deviations actually occur, you can address that part specifically. It is the difference between packing more insulation around everything just to be safe and knowing that the problem occurs during two hours on a loading dock.