Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%The air in the fridge doesn’t show the temperature of the vaccineThe Air in the Fridge Lies: How to Monitor the Real Temperature of Your Goods Without False AlarmsHow to show in seconds whether the load stayed at the right temperature and humidity during transportThe air feels heavy long before anyone measures it: how to make carbon dioxide levels visibleThe freezer showed -18 °C on Monday morning, but what happened over the weekend?The core temperature is what counts, and it only shows if someone has logged itTwo measuring points and the difference between them: how to make the temperature differential in a process visibleFour Measuring Points and a Time-Stamped Log Show Where the Heat in the Process Actually GoesYou Can’t Guess the Core Temperature of a Product: How to Document It Without Standing Next to ItThe fridge looked like it was holding the right temperature, but what happened overnight?Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%The air in the fridge doesn’t show the temperature of the vaccineThe Air in the Fridge Lies: How to Monitor the Real Temperature of Your Goods Without False AlarmsHow to show in seconds whether the load stayed at the right temperature and humidity during transportThe air feels heavy long before anyone measures it: how to make carbon dioxide levels visibleThe freezer showed -18 °C on Monday morning, but what happened over the weekend?The core temperature is what counts, and it only shows if someone has logged itTwo measuring points and the difference between them: how to make the temperature differential in a process visibleFour Measuring Points and a Time-Stamped Log Show Where the Heat in the Process Actually GoesYou Can’t Guess the Core Temperature of a Product: How to Document It Without Standing Next to ItThe fridge looked like it was holding the right temperature, but what happened overnight?

The 4–20 mA logger that tells you what the transmitter is really seeing: When an industrial sensor’s value has to be stored — not just passed along

Published July 3, 2026 at 13:46

Industrial control systems are built for real-time control, not for diagnostics. A 4–20 mA current loop from a pressure transmitter to the PLC is designed so that the control system can react quickly to changes. It is not designed so that the engineer can see what happened at 03:17 last night when the tank raised an alarm and then went quiet. The PLC’s own logging is limited, often as a matter of policy (the system shouldn’t become a distracting data hoarder) and sometimes because of technical constraints. When an intermittent problem needs to be tracked down, what you need is a standalone logger that sits in parallel with the existing loop and records everything, without affecting process control.

What a 4–20 mA logger does, technically

TandD TR-55I-MA is a compact current loop logger that measures the current level in a 4–20 mA loop. The instrument is connected as an additional load in the loop, or inductively via a custom shunt measurement, and records the current value at a user-selected interval. Its capacity is 16,000 data points, which at typical industrial intervals (for example, one reading per minute) covers about 11 days of continuous recording.

A range of up to 40 mA makes it possible to detect overloads (above the 20 mA maximum) that can occur with transmitter or cable faults. This is the same kind of overshoot that is often a diagnostic indicator and that an ordinary 4–20 mA monitor misses.

TandD TR-55I-MA kompakt 4-20 mA strömslinge-logger

Scale conversion — the key feature

A 4–20 mA signal is meaningless in itself. What does 8.3 mA from a pressure transmitter mean? It depends on the transmitter’s range: a transmitter with a 0–100 bar range converts 8.3 mA to (8.3−4)/(20−4) × 100 = 26.9 bar. A transmitter with a 0–10 bar range gives 2.69 bar. Without this conversion, raw mA data is just a meaningless series of numbers.

The TR-55I-MA has built-in scale conversion that performs the conversion directly in the logger. During configuration, the user enters the transmitter’s minimum and maximum values (for example, 0 bar and 100 bar), and the logger then stores values in the physical quantity: bar for pressure, l/min for flow, cm for level, kg for tank contents. When the data is transferred to a PC for analysis, all values are already in usable units.

This is especially valuable when several people analyze the same data, such as service technicians, product managers and PLC programmers. Everyone sees bar directly instead of having to do conversions in their heads.

Two logging modes — and why both exist

Instantaneous: Records the value at each logging point, exactly the value present at that moment. Suited to slow processes where individual readings are representative.

Average: Measures continuously during the logging interval and records the average value. Suited to rapidly varying processes (for example, pressure fluctuations from a piston pump) where a single momentary reading can be misleading.

The choice depends on what you are diagnosing. For slow-response measurements such as tank level, Instantaneous is the right choice. For analyzing pump stability or compressor cycling, Average is better.

Optical communication — why it matters

TandD’s TR-55 family uses optical data transfer via a USB cradle (56-TR-50U2), sold separately. The logger has no physical data connector. Instead, data is transferred through the housing via an LED and a photosensor.

This has several advantages in industrial environments:

  • No exposed connector means no path for moisture or corrosion to damage the electronics. The logger is IP-sealed and can stay that way.
  • Galvanic isolation between the logger and the computer. If the logger is in a floating-potential environment (near high voltage or frequency converters), the voltage doesn’t propagate to the computer.
  • No mechanical wear on the connector from repeated connections over the instrument’s lifetime.

The 4-year battery life (LS14250 lithium battery) means the logger can be installed and then simply have its data retrieved periodically, with no need to replace batteries or draw power from the control system.

Where the logger makes a real difference

Diagnosing intermittent problems: When a process sometimes alarms and sometimes works, you need data from those exact moments. A logger permanently installed in the loop captures the problem the first time it occurs, without a technician having to stand there.

Process characterization at installation: When commissioning new equipment, you need to understand how pressure, flow or level really vary over a day of operation. A logger on the loop provides that picture without burdening the PLC with extra logging tasks.

Energy data logging: Power meters (kWh meters or current transformers) with a 4–20 mA output are logged for energy optimization of buildings or industrial facilities. The data is used to identify unnecessary consumption cycles.

Environmental measurement in the field: Level gauges in geothermal wells, wind speed at wind turbines, solar radiation sensors at solar power plants, all with a 4–20 mA output. Standalone logging makes analysis possible without connecting to a CDS system.

Compressor and refrigeration systems: Pressure monitoring on the refrigerant side to detect cycling problems, operational disturbances or the need for service.

Water and wastewater systems: Flow measurement in pump systems, level measurement in cisterns and pump pits, pressure measurement in district heating networks.

Food production: Monitoring of pressure and flow in pasteurization steps, dosing of additives and temperature control loops. HACCP critical control points may require more detailed logging than the PLC normally provides.

Pharmaceutical production: GMP processes where every critical parameter must be traceable for each batch. Redundant logging in parallel with the main system provides an extra level of safety.

Laboratories and new installations: Development of new processes where you need to understand exactly how the measured values vary before the final production version is developed.

What you get for your money

A compact logger with a 4–20 mA input module (operational up to 40 mA), built-in scale conversion, 16,000 data point capacity, 15 fixed logging intervals (seconds to hours), two logging modes (Instantaneous or Average), an alarm LED to flag unusual values locally, 4-year battery life, optical communication for galvanic isolation, and a compact size (62×47×19 mm) for installation even in tight cabinets.

SEK 2,302 is the investment for a standalone single-channel logger. The 56-TR-50U2 USB cradle is sold separately and can be shared across several loggers if you are logging multiple parameters. For industrial engineering consultants, it is a cost-effective way to offer diagnostic services without having to rely on the customer’s PLC or SCADA system for data.

Read more: TandD TR-55I-MA 4-20 mA current loop logger in the shop →