Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%Four temperatures at once over a full working day reveal what spot checks missThe Freezer Lost Temperature Overnight – With a WiFi Logger You Know Before the Goods Are RuinedThe fridge read four degrees on Friday, but nobody knows what it did over the weekendOven temperatures are logged more reliably over a cable than over a WiFi connection that keeps droppingIs your fridge alarming unnecessarily? Measure the product temperature, not the airThe oven that stood open all night: how to detect temperature deviations before the product is ruinedCore temperature determines whether the cooling worked, not the room temperatureTwo measuring points, one alarm and no one needing to stand by the oven: how to monitor temperature remotelyMeasure inside the freezer, not outside it: a logger with an external probe gives you the temperature where it actually mattersThe core temperature of the product shows more than the oven displayVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%Four temperatures at once over a full working day reveal what spot checks missThe Freezer Lost Temperature Overnight – With a WiFi Logger You Know Before the Goods Are RuinedThe fridge read four degrees on Friday, but nobody knows what it did over the weekendOven temperatures are logged more reliably over a cable than over a WiFi connection that keeps droppingIs your fridge alarming unnecessarily? Measure the product temperature, not the airThe oven that stood open all night: how to detect temperature deviations before the product is ruinedCore temperature determines whether the cooling worked, not the room temperatureTwo measuring points, one alarm and no one needing to stand by the oven: how to monitor temperature remotelyMeasure inside the freezer, not outside it: a logger with an external probe gives you the temperature where it actually mattersThe core temperature of the product shows more than the oven display

Four temperatures at once over a full working day reveal what spot checks miss

Published 26 November 2026 at 10:06

The oven holds the right temperature when you check it, yet parts keep coming back with uneven hardening. Or the heating system works flawlessly in the morning and the complaints only start in the afternoon. The problem is rarely that the measurement is wrong. The problem is that it was taken once, in one place, at the wrong time.

4-kanals termometer med SD-logger

What the instrument is

This is a handheld thermometer with four inputs for thermocouples of types J, K, E, T, R and S. It can also be used with two channels for Pt100 probes. The display shows T1 to T4, or the difference between two points (T1-T2). Readings are saved with a real date and timestamp to an SD card in Excel format. A 2 GB card holds up to 20 million readings, and the sampling rate can be set between 1 and 3,600 seconds.

What problems it solves

With four channels you can compare several points during the same process, for example the front and rear edge of an oven or the supply and return of a pipe. The differential mode gives you the difference directly, without having to calculate it yourself. The offset function zeroes the instrument against a reference so that you can make relative measurements. Min/Max and Data Hold capture peaks that you would otherwise miss. Because the data is saved on the card, nobody has to stand by and write down values.

Three use cases

In the manufacturing industry it is used to map the temperature in heat-treatment furnaces, plastic presses and mould tools. Place the probes at different locations and run a full cycle. The curve shows where the heat lags behind and how long it takes to stabilise.

When installing and balancing heating and cooling systems, you measure supply and return temperature simultaneously with T1-T2. You can see whether the system delivers the temperature difference it was designed for, and you can document the result for the client.

In food production you record the cooling or heating of a product using several probes in different parts of the batch. Timestamped values are concrete evidence in your self-inspection program when you need to show that a process has stayed within the limit values.

Why it pays off

Manual logging ties up a person, and that person still leaves gaps between readings. With a logger you start the measurement, move on to other work and collect the card afterwards. Troubleshooting that used to take several days of repeated checks can often be settled by a single recorded cycle. The risk of rejected parts and complaints also decreases when the deviation can be documented rather than suspected. The delivery includes four type K wire probes, an SD card, six AA batteries and a hard case, so the instrument is ready to use right away.

If you need to document temperature profiles in more than one place at a time, this is an instrument that pays back the time quickly. Read more about the specifications via the link below.

Read more