Hoppa till innehåll
Free shipping on orders over 3000 SEK excl. VAT! Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%
Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%The fridge read four degrees on Friday, but nobody knows what it did over the weekendOven temperatures are logged more reliably over a cable than over a WiFi connection that keeps droppingIs your fridge alarming unnecessarily? Measure the product temperature, not the airThe oven that stood open all night: how to detect temperature deviations before the product is ruinedCore temperature determines whether the cooling worked, not the room temperatureTwo measuring points, one alarm and no one needing to stand by the oven: how to monitor temperature remotelyMeasure inside the freezer, not outside it: a logger with an external probe gives you the temperature where it actually mattersThe core temperature of the product shows more than the oven displayThe Cold Room That Lost Temperature on Friday Evening: How to Get the Alarm Before MondayThe furnace drifted overnight, but no one noticed until the batch was ruinedVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%The fridge read four degrees on Friday, but nobody knows what it did over the weekendOven temperatures are logged more reliably over a cable than over a WiFi connection that keeps droppingIs your fridge alarming unnecessarily? Measure the product temperature, not the airThe oven that stood open all night: how to detect temperature deviations before the product is ruinedCore temperature determines whether the cooling worked, not the room temperatureTwo measuring points, one alarm and no one needing to stand by the oven: how to monitor temperature remotelyMeasure inside the freezer, not outside it: a logger with an external probe gives you the temperature where it actually mattersThe core temperature of the product shows more than the oven displayThe Cold Room That Lost Temperature on Friday Evening: How to Get the Alarm Before MondayThe furnace drifted overnight, but no one noticed until the batch was ruined

Oven temperatures are logged more reliably over a cable than over a WiFi connection that keeps dropping

Published 24 November 2026 at 14:18

You have probably experienced this: a hardening furnace or drying cabinet went out of tolerance during the night, but the log has a gap right when it happened. The logger was installed at the far end of the hall, behind sheet-metal walls and machinery, and the WiFi signal dropped out. All that’s left is to guess what the temperature actually did.

TandD Logger för termoelement (typ K, J, T, E, S, R), 2 kanaler, trådbunden Ethernet/LAN. Molnuppkoppling

What the TR-75NW is

The TandD TR-75NW is a two-channel logger for type K, J, T, E, S and R thermocouples. The measuring range is -199 to +1760 °C, depending on which probe you connect. Probes are not included. They connect to screwless wire terminals for AWG 28–22 wire, with AWG 22 recommended. The logger is connected with a network cable (RJ45, 10/100 Mbps) and can be powered via PoE according to IEEE 802.3af. That means you only need a single cable to the measuring point.

What problems it solves

Measurement data is uploaded automatically over the wired network to the T&D WebStorage cloud service, or to your own PC running T&D Data Server. This means you no longer depend on wireless coverage in environments with metal, heat and interference. The logger also has its own memory for 16,000 readings, 15 fixed logging intervals and 15 upload intervals. This lets you log frequently but upload less often. The built-in LCD lets you read the temperature on site without a computer.

Accuracy for types K, J, T and E is ±(0.5 + 0.003 × t) °C, and for S and R ±(1.5 + 0.003 × t) °C. Cold junction compensation is ±0.5 °C at an ambient temperature of 10–40 °C.

Three situations where it works

Engineering and machining industry: In heat treatment and hardening, you want to be able to show that the furnace held the correct temperature throughout the entire cycle. With a type K probe in the furnace and one in the workpiece, you get the curve documented, and you can view it from the office.

Process industry and plastics: Drying cabinets, mold heaters and ovens are often located where network sockets already exist but WiFi doesn’t reach. PoE means the logger can be placed right where the probe is.

Food production: Industrial ovens, steam cookers and chilled process lines require documented temperature history. Type T thermocouples suit low temperatures, and type K covers most ovens. Both can be logged on the same unit.

Why it pays off

The cost of a missing log is seldom the logger itself. It is a rerun batch, a complaint or an audit where the documentation is missing. A logger with a wired connection reduces the risk of gaps and saves time, since nobody has to walk around reading values or collecting data manually. With two channels, you can also monitor both the oven chamber and the workpiece with a single unit.

If you need to document temperatures in an environment where wireless is not an option, the TandD TR-75NW is a practical way to get a continuous record.

Read more

More news

All news