Published 28 November 2026 at 16:56
It’s a common sight in kitchens, cold rooms and on loading docks: a sheet of paper on the wall where someone writes down the temperature twice a day. When a delivery is questioned or a refrigeration unit has stopped over the weekend, the paper shows only two points per day, and nobody can say what happened in between. That is a measurement problem, not a discipline problem.
What is the TandD 56-TR41A?
The 56-TR41A is a compact temperature logger with a built-in thermistor sensor in a fully sealed IP67-rated housing, which means it can withstand immersion in water. The logger connects directly to a phone or tablet via Bluetooth 4.2 Low Energy. No separate base unit or PC is needed. Configuration, readout and graph display are handled in the free T&D Thermo app, and reports can be generated in the TR4 Report app.
What problems does it solve?
The logger stores up to 16,000 measurement points with a resolution of 0.1 °C. Accuracy is ±0.3 °C between -20 and 80 °C. When reading it out, downloading the entire memory takes about 15 seconds. This means you can walk past, read it and carry on, instead of taking the logger out and connecting it to a computer. The logging interval is selected from 15 fixed steps from 1 second to 60 minutes, and one LS14250 battery lasts about 1.5 years. The built-in display shows the current temperature and a low-battery warning. Always check the measuring range in the datasheet against your application.
Three areas of use
Food transport. A logger placed in the load documents the entire journey. On arrival, the recipient reads it on their phone and creates a report that accompanies the delivery. This replaces handwritten notes and provides documentation if a complaint arises.
Freezer rooms and refrigeration circuits. The sealed housing withstands condensation, cleaning and cold. The logger can be hung at the point that is hardest to cool, for example at the far end by the door or near the evaporator, and read without anyone having to go in and open anything.
Greenhouses and process water. In humid environments where an ordinary logger would be damaged, the IP67 housing works. The maintenance department can follow the temperature over weeks and see whether a control loop is oscillating or whether a pump is running hot at night.
Why it pays off
The cost of poor temperature management is seldom the measurement itself. It lies in discarded goods, in rechecks and in the time spent searching for an explanation that cannot be substantiated. A logger that replaces manual readings saves working time every day, and a continuous curve lets you show that the goods stayed at the right temperature instead of assuming it. Since no base unit is needed, the investment is low, and each measuring point can be equipped individually.
If you need to document temperature in cold, humid conditions or during transport, the 56-TR41A is a straightforward and durable solution.