Hoppa till innehåll
Free shipping on orders over 3000 SEK excl. VAT! Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%
Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%Four measurement points over time reveal what a single thermometer missesThe freezer dropped ten degrees last night, but nobody noticed until morningFour temperatures at once over a full working day reveal what spot checks missThe Freezer Lost Temperature Overnight – With a WiFi Logger You Know Before the Goods Are RuinedThe fridge read four degrees on Friday, but nobody knows what it did over the weekendOven temperatures are logged more reliably over a cable than over a WiFi connection that keeps droppingIs your fridge alarming unnecessarily? Measure the product temperature, not the airThe oven that stood open all night: how to detect temperature deviations before the product is ruinedCore temperature determines whether the cooling worked, not the room temperatureTwo measuring points, one alarm and no one needing to stand by the oven: how to monitor temperature remotelyVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%Four measurement points over time reveal what a single thermometer missesThe freezer dropped ten degrees last night, but nobody noticed until morningFour temperatures at once over a full working day reveal what spot checks missThe Freezer Lost Temperature Overnight – With a WiFi Logger You Know Before the Goods Are RuinedThe fridge read four degrees on Friday, but nobody knows what it did over the weekendOven temperatures are logged more reliably over a cable than over a WiFi connection that keeps droppingIs your fridge alarming unnecessarily? Measure the product temperature, not the airThe oven that stood open all night: how to detect temperature deviations before the product is ruinedCore temperature determines whether the cooling worked, not the room temperatureTwo measuring points, one alarm and no one needing to stand by the oven: how to monitor temperature remotely

The freezer dropped ten degrees last night, but nobody noticed until morning

Published 27 November 2026 at 03:38

Many people have stood in front of a freezer that shows the correct temperature on its display, even though the compressor has been standing still for several hours during the night. The display only shows the current state. Nobody knows what happened at three o’clock, and by the time the deviation is discovered, the question of whether the goods can still be used has already been decided.

TandD Temperature logger, 2 channels (external probes), wireless WiFi LAN + Bluetooth. -60 to +155 °C depending on probe. Cloud connectivity

What the TR71A2 is

The TandD 56-TR71A2 is a temperature logger with two channels for external thermistor probes on a cable. It connects directly to your existing WiFi network, or a mobile hotspot, and uploads measurement data over encrypted HTTPS to the T&D WebStorage Service cloud. No separate base unit and no computer are needed during operation. The included probe is fluoropolymer-coated and measures from -60 to +155 °C, which covers everything from deep freezing to hot holding and processes close to ovens. Accuracy is ±0.3 to ±0.5 °C depending on the range.

What problems it solves

The logger replaces manual readings and binders with one continuous curve. The memory holds 30,000 data points. The logging interval can be set from one second to one hour, and the upload interval from one minute to 24 hours. Vaccine Mode records max and min values based on logged data, not just on what is displayed right now. It is VFC/CDC compliant and therefore relevant for pharmaceutical and vaccine refrigerators. The unit also supports WPA2-Enterprise, so it works in corporate networks where simpler WiFi devices are often rejected.

Three typical uses

Food production and commercial kitchens. Two probes in the same freezer room, or one in the fridge and one in the freezer, provide documentation for your self-inspection program. The curve also shows how long a door was left open or when a defrost cycle ran too long.

Pharmaceuticals and laboratories. Samples, reagents and vaccines require an unbroken temperature record. The max and min values over the entire logging period are what an auditor asks for.

Workshop and industry. In a hardening furnace, a heating cabinet or a cooling circuit, the probe is placed where the temperature actually needs to be measured, while the logger sits accessibly outside. With two channels you can compare inlet and outlet or two points in the same process.

Why it pays off

Consider a single lost pallet of refrigerated goods or a batch of samples that must be discarded. That costs more than the logger. On top of that comes the time spent on manual rounds and on compiling data ahead of an inspection. Because the logger uses the network that is already in place, you avoid extra equipment and installation. Configuration is done via Bluetooth with the T&D Thermo app, and USB is available for PC connection. Power comes from two AA batteries or via USB.

If you need to know what the temperature did when nobody was looking, a logger with cloud connectivity gives you the answer, instead of a display that only shows the current state.